We are Dental Supplier

Highlights
Beyond Ingenuity – Intelligent Endodontic Motor
Patency and Glide Path Have Never Been Easier
Tri Auto ZX2+ is equipped with a new generation reciprocating drive, OGP2, that greatly reduces the chance of a file breaking in the canal. This innovative motor can be used for patency, glide path, and shaping, allowing you to finish treatment safely and in less time. Additionally, with no limits on file size or cutting direction, your current file system is
compatible. The future of endodontic treatment is here. .. Tri Auto ZX2+.
Features
Next Level Reciprocation – Introducing OGP 2
OGP2 Function (Optimum Glide Path 2) Reduces the Chance of File Breakage
OGP2 dramatically reduces the chance of breaking files due to its new and innovative reciprocating motion. Even patency using a #10 scout file is possible. Notoriously difficult patency by hand filing can now be achieved by endo motor!
Rotation
Its intelligent motion reduces file binding and, when it does occur, helps prevent the file from breaking in the canal.

Maintains the Root Canal Shape
Even with curved or narrow root canals, OGP2 allows you to provide treatment that maintains the original root canal shape.

Handles Patency,Glide Path, and Shaping Using Just One Mode
From a #10 scout file, to the widest size available, the Tri Auto ZX2+ handles any CW/CCW file all in one mode. Patency, glide path, and shaping can all be performed with OGP2, allowing you to focus on treatment rather than settings.

OTR Mode Now Supports Both Reciprocation and Rotary Files
OTR (Optimum Torque Reverse) Offers Enhanced Safety and Performance

OTR technology offers superior safety while efficiently preparing the canal. Continuous rotation is maintained until the file encounters resistance in the curved and difficult part of the canal. Depending on the file load, the motor alternates between forward and reverse rotation with great sensitivity to prevent jamming and file breakage. OTR mode now supports reciprocation files in addition to rotary files. Modification of the cutting angle can be made to suit your needs.
OTR CW Mode
Cutting Direction: Clockwise (CW)
Non-Cutting Direction: Counterclockwise (CCW)
NEW! OTR CCW Mode
Cutting Direction: Counterclockwise (CCW)
Non-Cutting Direction: Clockwise (CW)
Suitable for Reciprocation files
World Leading Apex Location Built Right In
Root ZX Technology

Capable of high-precision measurement without being affected by dry or wet canals, the integrated apex locator allows you to perform treatment while continuously monitoring the position of the file. The Tri Auto ZX2+ also provides multiple safety features utilizing Root ZX’s proven accuracy to stop rotation and prevent over-instrumentation of the root canal.
Since 1992
Apical Slown Down

Activated when the OGP2 mode is operating, Apical Slow Down reduces the rotation speed of the file as it approaches the apex. This function allows you to provide treatment that simulates the feel of hand filing while also reducing the chance of file breakage.
Various Modes

Technical Detail
Specification
Name: | Tri Auto ZX2 |
Model: | TR-ZX2 |
Type: | PLUS |
Manufacturer: | J. MORITA MFG. CORP. |
Functions: | Apex location |
| OGP2 (Optimum Glide Path2) |
| OGP (Optimum Glide Path) |
| OTR (Optimum Torque Reverse) |
| OAS (Optimum Apical Stop) |
| OAS2 (Optimum Apical Stop2) |
| Auto Start / Stop, Auto Apical Reverse |
| Auto Apical Stop, Apical Slow Down |
| Torque Slow Down, Apical Torque Down |
| Auto Torque Reverse |
Accessories: | Tester, LS OIL |
| Power Plugs (one each of 4 types) |
| Probe Cord (0.75m) |
| File Holder, Contrary Electrodes |
| HP Protective Sleeve Type A |
Options: | Handpiece Holder, Long File Holder |
| External File Electrode (with cap) |
| Probe Cord (1.8m) |
Handpiece
Free Running Operation Speed: | 100 – 1000 rpm |
Torque: | 4 Ncm or more |
Battery: | Lithium-ion battery (DC 3.7 V) |
Weight: | Approx. 140 g (including battery |
Battery Charger
Rated Input Voltage: | DC 5 V |
Rated Input Current: | 2.4 A |
Weight: | Approx. 280 g (AC adapter not included) |
AC Adapter
Rated Input Voltage: | AC100 – 240 V |
Rated Input Frequency: | 47 – 63 Hz |
Rated Input Current: | 0.4A |
